PROJECT SUMMARY
Abnormality of the brachial plexus (BP), i.e. brachial plexopathy, can result in profound functional,
psychological and economic consequences. Dedicated peripheral nerve MRI, or MR neurography (MRN), is an
important adjunct to the physical exam and electrodiagnostic testing to evaluate brachial plexopathies, and
influences clinically decision making, including surgical planning, and outcomes. MRN affords direct visualization
of individual nerves and their relationship to osseus and soft tissue structures but suffers from insufficient spatial
resolution (~1.0mm-isotropic) resulting from poor signal-to-noise ratio (SNR). This is largely due to the inherently
concave anatomy of the neck-shoulder junction that precludes close proximity of conventional MRI coils to the
skin. The inherent, complex branching and intertwining anatomy of the BP requires higher spatial resolution
(~0.5 mm-isotropic) than possible with current radiofrequency (RF) coils. Current RF coils are either rigid or not
adequately flexible, and do not conform to the curvatures of the neck, shoulder and axillary regions.
We will develop novel, non-toxic, robust liquid metal RF coil technology to enable the design of a
conformal and flexible neck-BP array. This design will ensure that coil elements conform to the body contour (to
maximize SNR) in their entirety and with the arm in different positions. The characteristics of bendability and
form-fitting stretchability are feasible with liquid metal technology, but this technology has not been previously
implemented commercially. This project proposes the design and construction of a dedicated RF coil array for
brachial plexus MRN, to enable higher spatial-resolution and 3D imaging, with unprecedented detail, in patients
with clinically suspected thoracic outlet syndrome (TOS). We will systematically evaluate liquid metal coils
against standard coils for BP MRN. We hypothesize that the achievable spatial resolution will be ~0.5 mm
isotropic, greater than the ~1 mm isotropic currently achieved with commercial coils, and will therefore better
depict regional anatomy and pathology.
Impact: The proposed research will not only address TOS but will also facilitate evaluation of (1) other brachial
plexopathies and more peripheral neuropathies (of traumatic, inflammatory, iatrogenic etiologies, e.g.), and (2)
other complex/curved anatomies including the breast/chest wall region, perineal/groin region, and digits. This
technology would also facilitate dynamic imaging of the extremities to elucidate pathology such as
femoroacetabular impingement (hip), ligamentous laxity (multiple joints), and meniscal incompetence (knee), not
borne out with conventional, static MRI.
Public Health Relevance Statement
NARRATIVE
Novel, liquid metal RF coil technology will be developed to enable the design of a conformal and flexible
neck-brachial plexus coil array to deliver 3X-higher SNR. We hypothesize that the achievable spatial resolution
will be ~0.5 mm isotropic, greater than the ~1 mm isotropic currently afforded by commercial coils. This will
enable superior 3D resolution in brachial plexus magnetic resonance neurography, which will improve diagnosis
and impact non-operative and operative management.
National Institute of Biomedical Imaging and Bioengineering
CFDA Code
286
DUNS Number
060217502
UEI
YNT8TCJH8FQ8
Project Start Date
16-May-2022
Project End Date
28-February-2026
Budget Start Date
01-March-2024
Budget End Date
28-February-2025
Project Funding Information for 2024
Total Funding
$678,197
Direct Costs
$467,647
Indirect Costs
$210,550
Year
Funding IC
FY Total Cost by IC
2024
National Institute of Biomedical Imaging and Bioengineering
$678,197
Year
Funding IC
FY Total Cost by IC
Sub Projects
No Sub Projects information available for 5R01EB031820-03
Publications
Publications are associated with projects, but cannot be identified with any particular year of the project or fiscal year of funding. This is due to the continuous and cumulative nature of knowledge generation across the life of a project and the sometimes long and variable publishing timeline. Similarly, for multi-component projects, publications are associated with the parent core project and not with individual sub-projects.
No Publications available for 5R01EB031820-03
Patents
No Patents information available for 5R01EB031820-03
Outcomes
The Project Outcomes shown here are displayed verbatim as submitted by the Principal Investigator (PI) for this award. Any opinions, findings, and conclusions or recommendations expressed are those of the PI and do not necessarily reflect the views of the National Institutes of Health. NIH has not endorsed the content below.
No Outcomes available for 5R01EB031820-03
Clinical Studies
No Clinical Studies information available for 5R01EB031820-03
News and More
Related News Releases
No news release information available for 5R01EB031820-03
History
No Historical information available for 5R01EB031820-03
Similar Projects
No Similar Projects information available for 5R01EB031820-03