Three-dimensional, Portable, Inexpensive, and Reusable Tomographic Microscopy
Project Number5R03EB034871-02
Contact PI/Project LeaderDWORK, NICHOLAS
Awardee OrganizationUNIVERSITY OF COLORADO DENVER
Description
Abstract Text
PROJECT SUMMARY
Three-dimensional (3D) microscopy offers many promises for biological investigations and medical
applications. However, it is currently limited to well-resourced laboratories in settings with established
infrastructure. Many 3D microscopy techniques (e.g., confocal) rely on focusing light at an array of small
locations within the sample, which requires expensive and specialized equipment. Optical Projection
Tomography (OPT) is a 3D imaging technique that utilizes traditional microscopy equipment; instead of
focusing the light at specific locations, OPT images a sample from many angles to reconstruct a 3D volume.
It is a very effective method for 3D imaging of small translucent objects (e.g., mouse fetuses, parasites, and
large bacteria). While it is possible for OPT to be a lower-cost method of 3D microscopy, existing systems
remain expensive and large. We propose to take advantage of the ubiquitous and high-quality computing
and imaging hardware available in smartphones to make an OPT device that is inexpensive and extremely
portable. We will create a smartphone extension that robustly images a rotating sample and uses the
phone’s computational hardware to reconstruct the 3D volume. Two imaging modalities will be pursued:
visible-band attenuation microscopy (e.g., brightfield) and luminescent microscopy (e.g., bioluminescent).
The components of the smartphone extension are either 3D printed, laser cut acrylic, or readily commercially
available. Thus, the cost of manufacturing the device is extremely small and the total weight of the device is
very low; the total cost of all components will be less than $50. The components of the extension are easily
assembled on site, permitting the device to be transported with in a small package. Due to its low cost and
size, the OPT microscope can also serve as a useful tool for educational purposes (e.g., as part of an
undergraduate laboratory course involving optics) and for generating real data for tomographic algorithm
development. To validate the device, we will build two phantoms with three-dimensional features that allow
us to evaluate the Modulation Transfer Function: one for attenuation microscopy and another for luminescent
microscopy. Aim 1: Build a visible-band tomographic microscope extension to a smartphone. Aim 1A:
Implement 3D cone-beam reconstruction from visible-band sinogram data for samples approximately 10 mm
in size with approximately 10 µm resolution. Aim 1B: Improve the image resolution with a multi-lens optical
system. Aim 2: Implement bioluminescent tomographic microscopy by appropriately modifying the
tomographic reconstruction algorithm. Aim 3: Build two shelf-stable 3D phantoms with features of sizes
varying from 1 µm to 200 µm.
Public Health Relevance Statement
PROJECT NARRATIVE
Three-dimensional brightfield and bioluminescent microscopy has provided meaningful insights into biology
with small animals, parasites, and large bacteria. Existing tools that perform this type of imaging cost
between thousands and tens of thousands of US dollars, which limits the research to well-resourced
laboratories. We propose to use 3D printed parts, laser cut acrylic, and commercially available components
to create tomographic microscope of this type with a smartphone for less than $50, which would provide this
type of microscopy to less-resourced laboratories and to remote locations.
National Institute of Biomedical Imaging and Bioengineering
CFDA Code
286
DUNS Number
041096314
UEI
MW8JHK6ZYEX8
Project Start Date
01-July-2023
Project End Date
30-June-2025
Budget Start Date
01-July-2024
Budget End Date
30-June-2025
Project Funding Information for 2024
Total Funding
$74,711
Direct Costs
$59,173
Indirect Costs
$15,538
Year
Funding IC
FY Total Cost by IC
2024
National Institute of Biomedical Imaging and Bioengineering
$74,711
Year
Funding IC
FY Total Cost by IC
Sub Projects
No Sub Projects information available for 5R03EB034871-02
Publications
Publications are associated with projects, but cannot be identified with any particular year of the project or fiscal year of funding. This is due to the continuous and cumulative nature of knowledge generation across the life of a project and the sometimes long and variable publishing timeline. Similarly, for multi-component projects, publications are associated with the parent core project and not with individual sub-projects.
No Publications available for 5R03EB034871-02
Patents
No Patents information available for 5R03EB034871-02
Outcomes
The Project Outcomes shown here are displayed verbatim as submitted by the Principal Investigator (PI) for this award. Any opinions, findings, and conclusions or recommendations expressed are those of the PI and do not necessarily reflect the views of the National Institutes of Health. NIH has not endorsed the content below.
No Outcomes available for 5R03EB034871-02
Clinical Studies
No Clinical Studies information available for 5R03EB034871-02
News and More
Related News Releases
No news release information available for 5R03EB034871-02
History
No Historical information available for 5R03EB034871-02
Similar Projects
No Similar Projects information available for 5R03EB034871-02