Abstract Text
PROJECT SUMMARY/ABSTRACT
Despite great strides in improving the volume coverage, temporal resolution, and dose efficiency of clinical CT
scanners, the spatial resolution has plateaued since the mid-1980s. Nevertheless, there is a clear clinical need to
reveal a new level of anatomic detail for CT imaging in multiple areas, including assessment of bone fractures,
bone microarchitecture and fracture risk, spinal stenosis, spinal fusion healing after surgery, and cochlear im-
plant placement.
Various attempts have been made to improve the spatial resolution of CT, but the improvements have been
incremental and there is still no practical solution that can enable in vivo ultra-resolution imaging on standard
clinical CT scanners: a redesign of the CT detector array to one with finer pitched cells is very expensive for
widespread application, while high-resolution extremity CT and flat-panel CT have limited bore size and suffer
from inherent image quality issues, respectively.
We propose a new ultra-resolution CT technique, named “Zoomed-In Partial Scan” (ZIPS), to achieve a ma-
jor improvement in the spatial resolution of standard, clinical CT. The increased spatial resolution is achieved by
combining an extra small focal spot with a large magnification, and with innovative scanning schemes and re-
construction algorithms. The ZIPS method can be incorporated on existing standard clinical CT scanners, with-
out a costly redesign of the CT detector based on smaller cells or sacrificing image quality or dose efficiency in
regular scans. Compared with various specialized high-resolution research CT scanners, the proposed ZIPS
method leverages the accessibility, versatility, and wide volume coverage of standard clinical CT to provide an in
vivo ultra-resolution option for a wide patient population and various anatomical regions.
The project combines CT systems and reconstruction expertise at GE Research Center and clinical applica-
tion expertise at the Hospital for Special Surgery (HSS) and the Massachusetts Eye and Ear Institute (MEEI).
The GE Research Center team will perform all technical developments of this project. The HSS team will lead an
ex vivo validation study of the ZIPS CT technique applied to bone microstructure analysis, and compare results
with µCT gold standard and standard clinical CT. MEEI will provide clinical expertise in the evaluation of ZIPS
CT for temporal bone imaging.
Public Health Relevance Statement
PROJECT NARRATIVE
The spatial resolution of clinical CT scanners has plateaued since the mid-1980s, but a new level of anatomic de-
tail in CT imaging would be beneficial in multiple areas, including bone microarchitecture and fracture risk,
middle and inner ear diseases, and cochlear implant placement. We will develop a cost-effective CT technique to
double the spatial resolution of standard clinical CT scanners for imaging locally rigid anatomies.
National Institute of Biomedical Imaging and Bioengineering
CFDA Code
286
DUNS Number
UEI
G2JTZ3UQV9M3
Project Start Date
02-August-2020
Project End Date
30-April-2025
Budget Start Date
01-December-2023
Budget End Date
30-April-2025
Project Funding Information for 2022
Total Funding
$238,717
Direct Costs
$117,330
Indirect Costs
$121,387
Year
Funding IC
FY Total Cost by IC
2022
National Institute of Biomedical Imaging and Bioengineering
$238,717
Year
Funding IC
FY Total Cost by IC
Sub Projects
No Sub Projects information available for 6R01EB028270-04
Publications
Publications are associated with projects, but cannot be identified with any particular year of the project or fiscal year of funding. This is due to the continuous and cumulative nature of knowledge generation across the life of a project and the sometimes long and variable publishing timeline. Similarly, for multi-component projects, publications are associated with the parent core project and not with individual sub-projects.
No Publications available for 6R01EB028270-04
Patents
No Patents information available for 6R01EB028270-04
Outcomes
The Project Outcomes shown here are displayed verbatim as submitted by the Principal Investigator (PI) for this award. Any opinions, findings, and conclusions or recommendations expressed are those of the PI and do not necessarily reflect the views of the National Institutes of Health. NIH has not endorsed the content below.
No Outcomes available for 6R01EB028270-04
Clinical Studies
No Clinical Studies information available for 6R01EB028270-04
News and More
Related News Releases
No news release information available for 6R01EB028270-04
History
No Historical information available for 6R01EB028270-04
Similar Projects
No Similar Projects information available for 6R01EB028270-04