Description
Abstract Text
PROJECT SUMMARY/ABSTRACT
Half of the man-made radiation exposure to the U.S. population can be attributed to CT. Thus, stakeholders
have invested heavily in the reduction of CT doses. Recently, CT Deep Learning Reconstruction or Denoising
(DLRD) techniques have become available that claim to enable dose reduction in CT, just as CT iterative
reconstruction (IR) claimed before it. Like DLRD, IR showed dramatic apparent increases in image quality by
reducing image noise. Subsequent clinical studies found that true dose reductions capabilities for IR were only
20-25% in soft tissues and organs. Greater dose reductions resulted in compromised signal detectability for
low-contrast lesions (e.g., liver metastases). Now, DLRD algorithms are being used in clinical practice and
appear to yield image quality superior to IR. But again, we are finding that excessive radiation dose reduction
can introduce new artifacts and compromise lesion detectability. Our overall objective is to develop and
validate methods that can quantitatively determine CT protocols that deliver the needed diagnostic
performance at the lowest patient dose for any scanner model or reconstruction algorithm.
In our first two competitive award periods, we developed robust Channelized Hotelling model observers
(MOs) to quantify diagnostic performance using low contrast objects within a uniform phantom and validated
the work with large scale reader studies for both filtered back projection and IR images. We are deploying
these tools under EB028936 to allow robust dose optimization by CT users. However, there remain challenges.
First, low-contrast phantoms used with most MOs are too simple. Second, highly realistic lesion and noise
insertion tools require use of proprietary projection data and access to manufacturer software tools. Third, MOs
must be extended to work with DLRD methods and be generalizable to any scanner. The proposed work will
use patient image data, obviating the need for projection data, use our developed deep learning (DL)-MOs to
achieve a scalable solution for performance assessment, and be generalizable to any algorithm or scanner.
The goal of this renewal application is to develop robust DL-MO tools to efficiently predict diagnostic
performance for images created with DLRD methods. We will accomplish this through three specific aims:
1. Develop and validate disease-insertion and low-dose-simulation tools for CT DLRD techniques.
2. Develop and validate DL-MO tools to quantify mean diagnostic performance for DLRD methods.
3. Extend DL-MO methods to estimate performance variations across readers.
This work is the first to develop and use DL-MOs as accurate and efficient surrogates of human readers to
characterize task-specific performance of DLRD methods in CT using patient images. The resultant performance
assessment engine will facilitate training / testing of DL-based noise reduction algorithms and optimizing CT
protocols and doses. These significant capabilities will ensure that diagnostic performance and the lifesaving
diagnostic information obtained from CT are not compromised in DLRD-processed images.
Public Health Relevance Statement
PROJECT NARRATIVE
Missing a liver lesion, or other subtle pathology, can have life-or-death consequences for patients. However,
techniques that change CT images in a non-linear fashion are being commercially deployed based on
simplistic assessments, such as noise reduction, rather than on maintenance of diagnostic performance. This
work will provide the CT community tools to assess diagnostic performance for new CT imaging methods as
they become available, facilitating optimization of dose reduction and ensuring safe clinical deployment.
National Institute of Biomedical Imaging and Bioengineering
CFDA Code
286
DUNS Number
006471700
UEI
Y2K4F9RPRRG7
Project Start Date
20-September-2012
Project End Date
31-December-2027
Budget Start Date
01-January-2025
Budget End Date
31-December-2025
Project Funding Information for 2025
Total Funding
$511,186
Direct Costs
$319,036
Indirect Costs
$192,150
Year
Funding IC
FY Total Cost by IC
2025
National Institute of Biomedical Imaging and Bioengineering
$511,186
Year
Funding IC
FY Total Cost by IC
Sub Projects
No Sub Projects information available for 5R01EB017095-11
Publications
Publications are associated with projects, but cannot be identified with any particular year of the project or fiscal year of funding. This is due to the continuous and cumulative nature of knowledge generation across the life of a project and the sometimes long and variable publishing timeline. Similarly, for multi-component projects, publications are associated with the parent core project and not with individual sub-projects.
No Publications available for 5R01EB017095-11
Patents
No Patents information available for 5R01EB017095-11
Outcomes
The Project Outcomes shown here are displayed verbatim as submitted by the Principal Investigator (PI) for this award. Any opinions, findings, and conclusions or recommendations expressed are those of the PI and do not necessarily reflect the views of the National Institutes of Health. NIH has not endorsed the content below.
No Outcomes available for 5R01EB017095-11
Clinical Studies
No Clinical Studies information available for 5R01EB017095-11
News and More
Related News Releases
No news release information available for 5R01EB017095-11
History
No Historical information available for 5R01EB017095-11
Similar Projects
No Similar Projects information available for 5R01EB017095-11