Awardee OrganizationWILSON WOLF MANUFACTURING CORPORATION
Description
Abstract Text
DESCRIPTION (provided by applicant):
There exists a need for a single device that can culture, ship, and infuse islet. Flasks and petri dishes are the devices currently used to store islets. They are a weak link in the process because these devices have inherent design limitations that do not allow them to maintain islets at high viability during culture or shipping. The problem is the need to oxygenate islets by a gas/medium interface. The net result is that many devices are required for a single transplant, the process is not compatible with regulatory control, and precious islets are lost due to necrosis. There are no commercially available substitutes that offer a superior alternative.
This grant is focuses upon creating a gas permeable device that cultures, ships, and infuses islets at high viability in a manner compatible with regulatory control. This device will be superior to any commercially available alternatives. By eliminating the link between oxygen delivery and a gas/medium interface, a device that allows high density culture at high viability becomes available. The islets are at improved oxygen tension, with extra medium capacity, from culture through shipping. Primary and backup device configurations are proposed. One configuration is based on culturing islets at high density in an extremely easy to use device. A backup device integrates a high amount of surface area to house islets at a wide range of possible densities. Aim 1 determines which configuration will be pursued, and creates its design specifications. Of primary interest is the optimal gas permeable surface area to medium volume ratios that indicate device size and shape. Aim 2 produces small scale prototypes of the device and quantifies the performance relative to the flask using porcine and human islets, and provides design specifications for Aim 3. Aim 3 produces full scale device prototypes and quantifies the performance relative to the flask using porcine and human islets. If the novel device proves superior to the flask, specifications of the device will be delivered to Phase II which will investigate making the device suitable for shipping and infusing islets.
National Institute of Diabetes and Digestive and Kidney Diseases
CFDA Code
847
DUNS Number
170969237
UEI
L1HKPVNJ33J8
Project Start Date
30-September-2004
Project End Date
31-August-2006
Budget Start Date
30-September-2004
Budget End Date
31-August-2005
Project Funding Information for 2004
Total Funding
$422,593
Direct Costs
$337,192
Indirect Costs
$61,798
Year
Funding IC
FY Total Cost by IC
2004
National Institute of Diabetes and Digestive and Kidney Diseases
$422,593
Year
Funding IC
FY Total Cost by IC
Sub Projects
No Sub Projects information available for 1R43DK069865-01
Publications
Publications are associated with projects, but cannot be identified with any particular year of the project or fiscal year of funding. This is due to the continuous and cumulative nature of knowledge generation across the life of a project and the sometimes long and variable publishing timeline. Similarly, for multi-component projects, publications are associated with the parent core project and not with individual sub-projects.
No Publications available for 1R43DK069865-01
Patents
No Patents information available for 1R43DK069865-01
Outcomes
The Project Outcomes shown here are displayed verbatim as submitted by the Principal Investigator (PI) for this award. Any opinions, findings, and conclusions or recommendations expressed are those of the PI and do not necessarily reflect the views of the National Institutes of Health. NIH has not endorsed the content below.
No Outcomes available for 1R43DK069865-01
Clinical Studies
No Clinical Studies information available for 1R43DK069865-01
News and More
Related News Releases
No news release information available for 1R43DK069865-01
History
No Historical information available for 1R43DK069865-01
Similar Projects
No Similar Projects information available for 1R43DK069865-01