A Dual Energy X-Ray Detector for Digital Mammography
Project Number1R43EB003693-01A1
Contact PI/Project LeaderTUMER, TUMAY O
Awardee OrganizationNOVA R AND D, INC.
Description
Abstract Text
DESCRIPTION (provided by applicant):
We propose to develop a dual energy x-ray detector that will allow us to move towards an ideal digital radiography system for mammography. In our approach, we propose to implement a novel technology where the incoming x-ray photons are energy-separated. Compared to presently available dual energy radiography units, which use either filter-attenuated signals or consecutive high and low-energy exposures, our system will offer greater potential in detecting micro-calcifications as well as injected contrast agents without the disadvantages of present systems. It will also have high x-ray conversion efficiency, high limiting resolution, ultra-low noise, linear response and high dynamic range. A radiography system with such specifications offers the possibility not only of replacing x-ray films, but also improving image quality as well as providing opportunities for advanced breast imaging studies. It can also facilitate medical image management, computer-aided diagnosis and tele-mammography.
Our approach consists of developing a high-resolution detector. The incoming x-rays are detected inside high spatial and energy resolution detectors. The signal is input into each channel of a custom designed readout integrated circuit (1C). Each signal is then amplified, integrated and recorded. The processed signal is processed and reconstructed into a two-dimensional image. Finally the image is displayed on a high resolution monitor.
During Phase I, we will explore the feasibility of this novel concept mainly through computer simulations and discrete component testing of the critical circuits. At the end of Phase I the feasibility will be demonstrated and a preliminary design of proposed detector system will be ready. During Phase II we plan to design, fabricate and test a new custom 1C readout chip and incorporate it with a suitable detector. The new detector system's imaging capability and performance will be determined and characterized. We also plan to fabricate a small prototype detector arm to make larger area images to demonstrate the capability of the new dual energy detectors using mammography phantoms and excised tissue samples. During Phase III we will seek funding for clinical trials with our collaboration partners and demonstrate our prototype dual energy mammography system to potential Phase III commercialization partners.
We expect that our system will achieve significant improvements in both sensitivity and specificity in the detection of breast cancer. We thus anticipate that it will reduce both false negative and false positive results in breast cancer screening and eventually lead to saving more lives and reducing unnecessary trauma to patients.
National Institute of Biomedical Imaging and Bioengineering
CFDA Code
286
DUNS Number
173234451
UEI
M95NX1TLX4N9
Project Start Date
01-September-2005
Project End Date
31-August-2007
Budget Start Date
01-September-2005
Budget End Date
31-August-2007
Project Funding Information for 2005
Total Funding
$99,989
Direct Costs
$45,263
Indirect Costs
$48,185
Year
Funding IC
FY Total Cost by IC
2005
National Institute of Biomedical Imaging and Bioengineering
$99,989
Year
Funding IC
FY Total Cost by IC
Sub Projects
No Sub Projects information available for 1R43EB003693-01A1
Publications
Publications are associated with projects, but cannot be identified with any particular year of the project or fiscal year of funding. This is due to the continuous and cumulative nature of knowledge generation across the life of a project and the sometimes long and variable publishing timeline. Similarly, for multi-component projects, publications are associated with the parent core project and not with individual sub-projects.
No Publications available for 1R43EB003693-01A1
Patents
No Patents information available for 1R43EB003693-01A1
Outcomes
The Project Outcomes shown here are displayed verbatim as submitted by the Principal Investigator (PI) for this award. Any opinions, findings, and conclusions or recommendations expressed are those of the PI and do not necessarily reflect the views of the National Institutes of Health. NIH has not endorsed the content below.
No Outcomes available for 1R43EB003693-01A1
Clinical Studies
No Clinical Studies information available for 1R43EB003693-01A1
News and More
Related News Releases
No news release information available for 1R43EB003693-01A1
History
No Historical information available for 1R43EB003693-01A1
Similar Projects
No Similar Projects information available for 1R43EB003693-01A1