Autoverification of results generated by the automated analyzers is used by the clinical laboratories to increase efficiency, streamline the work flow and decrease turnaround time. However, this requires that the integrity of specimens is assured ?hemolyzed, lipemic and icteric specimens must be identified and rejection rules set to avoid verification of erroneous results. In our laboratory we measure the common chemistry analytes with Synchron LX20 Clinical System that offers index panel for identification of hemolyzed (H), lipemic (L) and icteric (I) specimens. We established the rejection rules by measuring H, I, and L for serum samples with known concentration of total hemoglobin (THgb =0-500 mg/dL, n=20), total bilirubin (TBil=1.9-28.4 mg/dL, n=36) and triglycerides (Trig=46-7370 mg/dL, n=29), and determined the effect of H, I and L values on 29 common serum chemistry analytes. None of the studied serum analytes were affected when I<= 28 and the rejection limit was set to be >28. Following analytes were affected at increased L values: HDLC, LDLC (L>2), DBil, TBil (L>4), Alb, CO2 (L>5), and at increased H values: LD and Fe (H>1), K (H>2), AST, CK, DBil, TBil (>3), AMYL (H>4), ALT (>6), Na (>8) and, therefore, these L and H values were set as the rejection limits. For the remaining analytes the rejection limits were set as L>8 and H>9. Whenever the I or H limit was exceeded the test was reported as icteric or hemolyzed, while specimen with rejected L limit, except for LDLC, were ultracentrifuged and reanalyzed. Implementation of these rejection limits on the number of affected specimen / tests in the calendar year 2003 is summarized as follows: 986 specimens (0.89% of total) were received hemolyzed (H=2, n=318; H=3, n=310, H=4, n=448, H=5, n=292, H=6, n=132, H=7, n=112; H=8, n=122; H=9, n=145; H=10, n=894) resulting in 2773 tests reported as ?hemolyzed?; 244 specimens (0.22% of total) needed to be ultracentrifuged. There were no specimens with I>28.
Cost analysis: In our laboratory the serum index panel is performed automatically with each of the 29 LX20 methods. For these tests, on average, the cost per test increased by $0.013 that translates to an increase in the cost per year by 5.49%.
No Sub Projects information available for 1Z01CL010001-29
Publications
Publications are associated with projects, but cannot be identified with any particular year of the project or fiscal year of funding. This is due to the continuous and cumulative nature of knowledge generation across the life of a project and the sometimes long and variable publishing timeline. Similarly, for multi-component projects, publications are associated with the parent core project and not with individual sub-projects.
No Publications available for 1Z01CL010001-29
Patents
No Patents information available for 1Z01CL010001-29
Outcomes
The Project Outcomes shown here are displayed verbatim as submitted by the Principal Investigator (PI) for this award. Any opinions, findings, and conclusions or recommendations expressed are those of the PI and do not necessarily reflect the views of the National Institutes of Health. NIH has not endorsed the content below.
No Outcomes available for 1Z01CL010001-29
Clinical Studies
No Clinical Studies information available for 1Z01CL010001-29
News and More
Related News Releases
No news release information available for 1Z01CL010001-29
History
No Historical information available for 1Z01CL010001-29
Similar Projects
No Similar Projects information available for 1Z01CL010001-29