Project 3: Continuous Wave Electron Paramagnetic Resonance Imaging. Summary of Progress: We have modified our existing 300 MHz CW machine by supplementing a field sweep coil that can work at high AC frequencies. We tested the existing gradient coils for high frequency operation, and found that they can be used only up to a frequency of 1 kHz. By employing field sweeps at 0.33 kHz, and rotating gradients at 1 kHz (by applying sinusoidal gradients in two orthogonal gradient coils we could accomplish a left- or right-rotating gradient current corresponding to 2G/cm amplitude) required for 2D imaging. The lower frequency rapid scan signal, the three higher frequency gradient signals, and the trigger signals for data acquisition were generated using National Instruments LabView software and National Instrument PCI-6289 multifunction data acquisition card. The amplitudes of the gradient signals are adjusted to result in a circularly polarized gradient field rotating in the XZ plane at the selected frequency. The phase of the X and Z gradients can then be incremented programmatically relative to the rapid scan field at a desired step interval. The EPR signals from the RF bridge are down-converted to base band and amplified using a low noise low frequency amplifier and captured using a commercial digitizer-cum-summer Acqiris AP100 (Acqiris USA, Monroe, CA) dual channel Signal. By further applying a sinusoidal current in the third orthogonal coil, one can tilt the rotating gradient plane in equal tilt angles to cover an entire hemisphere of gradient trajectories centered on the resonator that is required for 3D spatial encoding. Since the projections are collected with the sweep field and simultaneous gradient rotation, one has to reorganize the observed signals by a simple matrix shuffling program to give the conventional Cartesian projections which are then used to generate the image by filtered back-projection. Even with this modest sweep frequency each projection could be carried out in less than 15 ms. We could collect 2D and 3D projection data in this so-called Rapid-scan-rotating gradient modality at least 50-100 times faster than the conventional CW approach. The invention has been protected by a US application.
No Sub Projects information available for 1Z01BC010478-05
Publications
Publications are associated with projects, but cannot be identified with any particular year of the project or fiscal year of funding. This is due to the continuous and cumulative nature of knowledge generation across the life of a project and the sometimes long and variable publishing timeline. Similarly, for multi-component projects, publications are associated with the parent core project and not with individual sub-projects.
No Publications available for 1Z01BC010478-05
Patents
No Patents information available for 1Z01BC010478-05
Outcomes
The Project Outcomes shown here are displayed verbatim as submitted by the Principal Investigator (PI) for this award. Any opinions, findings, and conclusions or recommendations expressed are those of the PI and do not necessarily reflect the views of the National Institutes of Health. NIH has not endorsed the content below.
No Outcomes available for 1Z01BC010478-05
Clinical Studies
No Clinical Studies information available for 1Z01BC010478-05
News and More
Related News Releases
No news release information available for 1Z01BC010478-05
History
No Historical information available for 1Z01BC010478-05
Similar Projects
No Similar Projects information available for 1Z01BC010478-05