Enhanced quantitative imaging of compound action potentials in multi-fascicular peripheral nerve with fast neural Electrical Impedance Tomography enabled by 3D multi-plane softening bioelectronics
Project Number1OT2OD026545-01
Contact PI/Project LeaderHOLDER, DAVID S
Awardee OrganizationUNIVERSITY COLLEGE LONDON
Description
Abstract Text
Electrical Impedance Tomography (EIT) is a new medical imaging method which, uniquely, offers a way to image
neuronal depolarization in nervous tissue using arrays of external electrodes. In rat cerebral cortex, it has a
resolution of <200µm and 1 ms using epicortical electrode arrays during sensory evoked potentials. It has been
pioneered by PI David Holder at UCL London who has recently extended it to imaging compound action potential
traffic within nerves with a flexible silicone rubber cylindrical cuff. The same cuff may then also be used for selective
stimulation of the identified fascicles. This has been supported by Galvani Bioelectronics as it could furnish an
essential way to avoid off-target effects in Electroceutical stimulation of autonomic nerve. Until now, it has been
undertaken using an external cylindrical cuff with 16-32 electrodes. Spatial resolution is good at the edge of the
nerve near the electrodes but decreases towards the centre of the nerve where current density is less. Our objective
is to improve spatial resolution by adapting the cuff to have a “cartwheel” design with spokes extending into the
interior of the nerve. Penetrating intraneural electrodes are rigid and cause nerve damage, inflammation, and loss of
recording ability. However, we mitigate this risk by the use of novel “shape memory polymer” pioneered by co-PI
Walter Voit at University of Texas Dallas (UTD). This is rigid at room temperature, so permitting insertion, but
becomes flexible at body temperature so that it is biocompatible and does not elicit an inflammatory response. This
would permit higher spatial resolution in the interior of the nerve in imaging while also offering a way to achieve
selective stimulation of identified fascicles impossible with an external cylindrical cuff alone.
In year 1 we will undertake preliminary studies with different electrode materials and a preliminary
geometry of 4 spokes with 4 electrodes each. This will be tested in saline filled tanks, sheep vagus ex and in vivo, and
rabbit sciatic nerve in vivo. In Year 2, further acute studies in rabbit sciatic and sheep vagus nerve during evoked
activity will be undertaken with an improved electrode geometry suggested by modelling and empirical studies in
Year 1, with up to 16 spokes with 16 electrodes each. In Year 3, we will evaluate the biocompatibility and
performance in imaging in chronic studies over up to 3 months in sheep vagus nerve and an acute pilot study in
human vagus nerve in subjects where the nerve is exposed for insertion of a vagal nerve stimulator. In parallel, we
will optimise EIT imaging reconstruction methods, combine EIT academic software into a robust package ready for
use in clinical trials, and develop a mechanical electrode insertion rig which can be inserted through an endoscope.
In all animal studies, performance will be assessed by histology, electrophysiology and EIT imaging.
The deliverable will be a novel “cartwheel” electrode design for high resolution EIT imaging in nerve, and a
rigorous evaluation of its performance and biocompatibility. We envisage that it will cause negligible nerve damage
when used over months and deliver imaging of fascicular compound action potentials throughout the cross section
of the nerve with an accuracy of <150µm and 1ms for human vagus nerve.
Public Health Relevance Statement
There is great current interest in treating conditions such as epilepsy or arthritis by electrical stimulation
of nerves in the body. Unfortunately, this will be limited if there is inadvertent stimulation of nerve
fibres leading to organs besides those necessary. We propose development of a new electrode cuff
“cartwheel” design that will enable detailed imaging and then selective stimulation of the correct fibres,
using the new medical imaging method of fast neural Electrical Impedance Tomography.
No Sub Projects information available for 1OT2OD026545-01
Publications
Publications are associated with projects, but cannot be identified with any particular year of the project or fiscal year of funding. This is due to the continuous and cumulative nature of knowledge generation across the life of a project and the sometimes long and variable publishing timeline. Similarly, for multi-component projects, publications are associated with the parent core project and not with individual sub-projects.
No Publications available for 1OT2OD026545-01
Patents
No Patents information available for 1OT2OD026545-01
Outcomes
The Project Outcomes shown here are displayed verbatim as submitted by the Principal Investigator (PI) for this award. Any opinions, findings, and conclusions or recommendations expressed are those of the PI and do not necessarily reflect the views of the National Institutes of Health. NIH has not endorsed the content below.
No Outcomes available for 1OT2OD026545-01
Clinical Studies
No Clinical Studies information available for 1OT2OD026545-01
News and More
Related News Releases
No news release information available for 1OT2OD026545-01
History
No Historical information available for 1OT2OD026545-01
Similar Projects
No Similar Projects information available for 1OT2OD026545-01