Development of Modular Synthetic Sensors for Protein Biomarker Detection
Project Number5R01EB033412-02
Former Number1R01EB033412-01
Contact PI/Project LeaderMOVILEANU, LIVIU
Awardee OrganizationSYRACUSE UNIVERSITY
Description
Abstract Text
Project summary
Protein detection and biomarker profiling have wide-ranging significance in many areas of disease prognostics,
diagnostics, and therapeutics. For example, the progression and development of various cancers are
accompanied by alterations in specific protein expressions. These variations in different biofluids are indicative
of disease-like conditions. A long-standing difficulty of existing methods is the detection of multiple proteins in a
complex biological sample with high sensitivity and a broad dynamic range. In addition, scalable protein
identification and quantification techniques are usually created with sacrificed sensitivity, so their applicability in
clinical settings remains limited. To overcome these fundamental and technical shortcomings, we will develop,
optimize, and validate a next-generation class of sensing elements for targeted protein biomarker detection at
single-recognition event precision. These proposed studies aim to engineer synthetic sensors made of a
single-polypeptide chain protein nanostructure. This protein nanostructure encompasses a membrane protein
pore and a programmable protein binder. The protein pore is a reporter that generates an output signature,
which depends on the identity and quantity of the biomarker. A programmable binder is a small antibody-
mimetic scaffold, such as a monobody or an affibody, sampling the targeted biomarker in solution. Hence, a
generic binder can be modified for multiple protein analytes. This way, such a modular design significantly
expands the utility of these sensing elements for numerous biomarkers while preserving their high sensitivity
and specificity using the resistive-pulse technique. This critical benefit is facilitated by the genetically encoded
nature of these sensors so that they can form combinatorial libraries of tethered binders. These manipulations
of modular pore-based detectors equipped with antibody-mimetic binders have not been conducted previously.
They are intended for use in challenging biofluids, where specific binder-biomarker interactions will be
unambiguously distinguished from nonspecific interactions of the medium constituents. Further advantages of
this real-time and label-free technology include maintaining an amplified signal-to-noise ratio in a wide dynamic
range due to the superior bandwidth of time-resolved electrical recordings. The expected immediate outcomes
of these proposed studies will be the following: (i) development, optimization, and validation of monobody- and
affibody-based sensors for protein detection; (ii) protein biomarker detection in multiplexed and high-
throughput formulations; (iii) protein biomarker detection in heterogeneous solutions. These results will
represent a platform for fingerprinting panels of multiple protein targets in biofluids without impairing the
sensitivity of these determinations. This proposed research will impact quantitative proteomics and biosensor
technology by providing a fundamental basis and tools for ultrasensitive biomarker detection.
Public Health Relevance Statement
Project Narrative
Protein identification and quantification in challenging heterogeneous biofluids have pivotal significance in
biomarker discovery. These proposed studies will impact healthcare by providing technological tools for
ultrasensitive protein detection in biomedical diagnostics, quantitative proteomics, and molecular therapeutics.
National Institute of Biomedical Imaging and Bioengineering
CFDA Code
286
DUNS Number
002257350
UEI
C4BXLBC11LC6
Project Start Date
01-March-2023
Project End Date
28-February-2027
Budget Start Date
01-March-2024
Budget End Date
28-February-2025
Project Funding Information for 2024
Total Funding
$379,576
Direct Costs
$280,256
Indirect Costs
$99,320
Year
Funding IC
FY Total Cost by IC
2024
National Institute of Biomedical Imaging and Bioengineering
$379,576
Year
Funding IC
FY Total Cost by IC
Sub Projects
No Sub Projects information available for 5R01EB033412-02
Publications
Publications are associated with projects, but cannot be identified with any particular year of the project or fiscal year of funding. This is due to the continuous and cumulative nature of knowledge generation across the life of a project and the sometimes long and variable publishing timeline. Similarly, for multi-component projects, publications are associated with the parent core project and not with individual sub-projects.
No Publications available for 5R01EB033412-02
Patents
No Patents information available for 5R01EB033412-02
Outcomes
The Project Outcomes shown here are displayed verbatim as submitted by the Principal Investigator (PI) for this award. Any opinions, findings, and conclusions or recommendations expressed are those of the PI and do not necessarily reflect the views of the National Institutes of Health. NIH has not endorsed the content below.
No Outcomes available for 5R01EB033412-02
Clinical Studies
No Clinical Studies information available for 5R01EB033412-02
News and More
Related News Releases
No news release information available for 5R01EB033412-02
History
No Historical information available for 5R01EB033412-02
Similar Projects
No Similar Projects information available for 5R01EB033412-02