Highly Oriented PEEK/PEEK Composites for Dental Implant
Project Number5R44DE012558-03
Contact PI/Project LeaderSHALABY, SHALABY W
Awardee OrganizationPOLY-MED, INC.
Description
Abstract Text
The Phase I study demonstrated the feasibility that highly oriented PEEK and carbon-fiber-reinforced PEEK (CFR-PEEK) could be engineered as surface phosphonylated dental implants and these implants could be microtextured to enhance osseointegration. In the Phase I study, surface-phosphonylated and microtextured rods composed of solid-state oriented PEEK and CRF-PEEK were implanted transcortically in edentulous mandibles in goats and were assessed at 12 weeks for osseointegration. The results indicated (1) solid-state orientation of PEEK increased modulus; (2) phosphonylation of PEEK promoted osseointegration; and (3) osseointegration was further enhanced by surface microtexturing and immobilizing calcium to the phosphonylated PEEK surface. These results and additional studies at Poly-Med on PEEK clearly indicate several polymer engineering options can produce an optimum endosteal dental implant (EDI). Therefore, the options for the Phase II study will include solid-state orientation, fiber-ultradrawing, surface phosphonylation, fiber reinforcement, and self-reinforcement of PEEK. The ultimate goal for the Phase II study will be to engineer a novel cementless, EDI that will not have the biological and biomechanical deficiencies of metallic EDIs. Phase II objectives are consistent with this goal and will be to (1) use surface phosphonylation, solid-state orientation, and radiochemical sterilization, for optimized preparation of solid-state oriented PEEK, CFR-PEEK composites, and fiber self- reinforced PEEK composites; (2) design and construct three types of EDIs, implant in a dog model, quantitate biological responses intraorally, and compare to a commercial titanium EDI; (3) select one type of PEEK-based EDI for optimizing and finalizing plans for Phase III; and (4) identify a marketing partner for collaboration for planning and executing Phase III. Phase III efforts will address (1) final development and scale-up of the selected EDI and (2) conducting relevant studies to meet regulatory approval. PROPOSED COMMERCIAL APPLICATION: Phase II results will provide critical data for finalizing the selected endosteal implant for pilot-scale production and executing the safety and clinical studies in Phase III. Successful completion of Phase III will lead to the first introduction of a cementless, polymeric EDI for anchoring artificial teeth and bridging to natural ones. This technology will also be extended to several orthopedic applications.
Public Health Relevance Statement
Data not available.
NIH Spending Category
No NIH Spending Category available.
Project Terms
acylation biomaterial development /preparation biomaterial interface interaction biomechanics calcium carbon composite resins dogs endosseous dental implant histology hydrolysis ketones medical implant science polyethylene glycols radiochemistry scanning electron microscopy solid state toluene
National Institute of Dental and Craniofacial Research
CFDA Code
121
DUNS Number
839420742
UEI
L67LQ9NBEMB7
Project Start Date
01-February-1998
Project End Date
31-May-2004
Budget Start Date
01-June-2003
Budget End Date
31-May-2004
Project Funding Information for 2003
Total Funding
$375,157
Direct Costs
$268,826
Indirect Costs
$104,103
Year
Funding IC
FY Total Cost by IC
2003
National Institute of Dental and Craniofacial Research
$375,157
Year
Funding IC
FY Total Cost by IC
Sub Projects
No Sub Projects information available for 5R44DE012558-03
Publications
Publications are associated with projects, but cannot be identified with any particular year of the project or fiscal year of funding. This is due to the continuous and cumulative nature of knowledge generation across the life of a project and the sometimes long and variable publishing timeline. Similarly, for multi-component projects, publications are associated with the parent core project and not with individual sub-projects.
No Publications available for 5R44DE012558-03
Patents
No Patents information available for 5R44DE012558-03
Outcomes
The Project Outcomes shown here are displayed verbatim as submitted by the Principal Investigator (PI) for this award. Any opinions, findings, and conclusions or recommendations expressed are those of the PI and do not necessarily reflect the views of the National Institutes of Health. NIH has not endorsed the content below.
No Outcomes available for 5R44DE012558-03
Clinical Studies
No Clinical Studies information available for 5R44DE012558-03
News and More
Related News Releases
No news release information available for 5R44DE012558-03
History
No Historical information available for 5R44DE012558-03
Similar Projects
No Similar Projects information available for 5R44DE012558-03